Drift Eliminators

High-Efficiency Drift Eliminators

Cellular

CF150MAx Counterflow Cellular Drift Eliminators

CF150MAx Counterflow Cellular Drift Eliminators are specifically-designed to achieve maximum drift removal efficiency in counterflow tower applications while keeping pressure drop significantly lower than in cellular drift eliminators designed for crossflow cooling towers.

Cellular Drift Eliminators

The modules are constructed of a series of sinusoidal-shaped corrugated CTI STD-136 PVC sheets that are mechanically assembled to mating sinusoidal structural waves to form closed cells. These cells force the drift droplets carried in the leaving airstream to make three distinct changes in direction. This disruption of the air flow creates centrifugal forces on the drift droplets, forcing them to be captured by inertial impaction and direct interception with the module walls and thereby removed from the airstream.

air flow

Features and Benefits

checkmark High surface area (cell dimension of 1.50″ [38mm]) provides maximum performance at minimum pressure drop.
checkmark CF150MAx modules “nest” with the modules next to them (below left) to provide “seamless” drift removal. This nesting design makes the nested space between packs a fully-functioning drift removal cell instead of a “dead space” that can allow drift droplets to completely bypass the drift eliminators (below right).
Nested & Flat Seam
checkmark Patented “MA” (Mechanical Assembly) Technology for environmentally-friendly glue-free packs that can be assembled on-site
checkmark CF150MAx modules are strong enough to span 6 ft (1.8 m), requiring fewer support beams and less air blockage.
checkmark Can be field cut for a tight fit around columns and other structures without sacrificing structural integrity.

Applications

The CF150MAx is designed for applications requiring very low drift levels in counterflow Cooling Towers, Evaporative Cooling systems, Scrubbers, and High Humidity Cooling systems.

Product Weights / Span Capabilities

Sheet Thickness Dry Weight Maximum Span *
lbs/ft2 kg/m2
.015″ (.38mm) Standard 1.0 4.9 4 ft (1.2m)
.020″ (.51mm) 1.3 6.3 6 ft (1.8m)

Tested at a maximum of 115° F (46° C) with 2.0" (51mm) wide supports. Tested at a maximum of 115° F (46° C) with 2.0″ (51mm) wide supports.

Product Dimensions

Cell Size Module Dimensions
Depth Width Standard Length
1.500″ (38.1 mm) 5.25″ (133 mm) 12″ (305 mm)
or 18″ (457 mm)
2 to 12 ft.
in 2 ft. increments
(610 to 3658 mm
in 610 mm increments)

Drift Loss

.001% recirculation (Test Method CTI-HBIK Standard 140) is possible in new installations that are properly designed and installed and take advantage of the CF150MAx’s fully-nesting design and Brentwood DriSeals. Retrofitting older cooling towers with CF150MAx Counterflow Drift Eliminators will also result in significant improvement in drift emissions.

Pressure Drop Curve

See CTI Technical Paper TP06-11 for comparative pressure drop tests of competing cellular drift eliminators.

Pressure Drop Curve

Materials

CF150MAx Counterflow Cellular Drift Eliminators are made from PVC material that meets CTI (Cooling Tower Institute) Standard 136 and are UV protected. The PVC compounds used in Brentwood cellular drift eliminators have outstanding resistance to weather exposure, and are nearly impervious to chemical degradation by alkalis and acids, grease, fats, oils, and biological attack. PVC has an excellent fire rating due to its self-extinguishing characteristics.

CF80MAx Counterflow Cellular Drift Eliminators

CF80MAx Counterflow Cellular Drift Eliminators are specifically-designed to achieve maximum drift removal. Unlike other drift eliminators designed for both counterflow and crossflow towers, Brentwood’s counterflow eliminators have significantly lower pressure drop than dual-purpose eliminators

CF80MAx Counterflow Cellular Drift Eliminators

The modules are constructed of a series of sinusoidal-shaped corrugated CTI STD-136 PVC sheets that are mechanically assembled to mating sinusoidal structural waves to form closed cells. These cells force the drift droplets carried in the leaving airstream to make three distinct changes in direction. This disruption of the air flow creates centrifugal forces on the drift droplets, forcing them to be captured by inertial impaction and direct interception with the module walls and thereby removed from the airstream.

air flow

Features and Benefits

checkmark Beveled Drainage Tip design reduces pressure drop by up to 25% (based on air velocity of 800fpm [4.1m/s] over non-beveled design
checkmark Patented “MA” (Mechanical Assembly) Technology for environmentally-friendly glue-free packs.
checkmark Heavy Duty CF80MAx modules are strong enough to span 6 ft (1.8 m), requiring fewer support beams and less air blockage.
checkmark Can be field cut for a tight fit around columns and other structures without sacrificing structural integrity. Dri-Seals are recommended for maximum performance.
checkmark

All Brentwood Cellular Drift Eliminators modules “nest” with the modules next to them (below left) to provide “seamless” panel installations.

Nested & Flat Seam

Applications

The CF80MAx is designed for applications requiring very low drift levels in counterflow Cooling Towers, Evaporative Cooling systems, Turbine Intake Hoods, and Scrubbers, providing the best drift removal efficiency. With field-verified drift test results of .0004% per CTI Standard 140 (the industry standard for testing of cooling tower drift), there is no need to use double layers of drift eliminators to achieve high drift-reduction efficiency.

Product Weights / Span Capabilities

Sheet Thickness Dry Weight Maximum Span *
lbs/ft2 kg/m2
.013″ (.33mm) Standard 1.6 7.8 4 ft (1.2m)
.020″ (.51mm) Heavy Duty 2.2 10.7 6 ft (1.8m)

Tested at a maximum of 115° F (46° C) with 2.0" (51mm) wide supports. Tested at a maximum of 115° F (46° C) with 2.0″ (51mm) wide supports.

Product Dimensions

Cell Size Module Dimensions
Depth Width Standard Length
.86″ (21.8 mm) 5.25″ (133 mm) 12″ (305 mm)
or 18″ (457 mm)
2 to 12 ft. (610 to 3658mm)
in 1 ft. (305mm) increments
up to 6 ft. (1829mm) and in
2 ft. (610mm) increments over 6ft. (1829mm)

Drift Loss

.0005% recirculation (Test Method CTI-HBIK Standard 140) is possible in new installations that are properly designed and installed and take advantage of the CF80MAx’s fully-nesting design and Brentwood DriSeals. Retrofitting older cooling towers with CF80MAx Counterflow Drift Eliminators will also result in significant improvement in drift emissions.

Pressure Drop Curve

See CTI Technical Paper TP06-11 for comparative pressure drop tests of competing cellular drift eliminators.

Pressure Drop Curve

Materials

All Brentwood Cellular Drift Eliminators are made from PVC material that meets CTI (Cooling Tower Institute) Standard 136 and are UV protected. These PVC compounds have outstanding resistance to weather exposure, and are nearly impervious to chemical degradation by alkalis and acids, grease, fats, oils, and biological attack. PVC has an excellent fire rating due to its self-extinguishing characteristics.

XF80MAx Counterflow Cellular Drift Eliminators

XF80MAx Crossflow Cellular Drift Eliminators provide the best available drift removal efficiency on the market today. The upward flow path, steep water drainage angle, and “tuned venturi section” make this the ideal product for factory-built crossflow towers

XF80MAx Crossflow Cellular Drift Eliminators

Brentwood ACCU-PAC Cellular Drift Eliminator modules are constructed of a series of sinusoidal-shaped, corrugated, CTI STD-136, PVC sheets that are mechanically assembled to mating sinusoidal structural waves to form closed cells. These cells force the drift droplets carried in the airstream to make three distinct changes in direction. This diversion of the air flow creates centrifugal forces on the drift droplets, forcing them to be captured by inertial impaction with the cell walls and thereby removing the droplets from the airstream.

air flow

Features and Benefits

checkmark The upward flow path and steep water drainage angle maximizes the drift removal for crossflow applications, making it fully-effective even when installed vertically.
checkmark The engineered venturi design (right) increases the velocity of the exit airflow to “scrub out” smaller droplets.
checkmark The .86” (21.8 mm) flute spacing effectively removes drift (at the lowest pressure drop) in crossflow towers with high air velocities up to 800 fpm (4.0 m/s).
checkmark Raw material meets CTI Standard 136 and has a flame spread rating of 25 or less per ASTM E84.
checkmark

XF80MAx modules “nest” with the modules next to them (below left) to provide “seamless” drift removal. This nesting design makes the nested space between packs a fully-functioning drift removal cell instead of a “dead space” that can allow drift droplets to completely bypass the drift eliminators (below right).

Nested Seam & Flat Seam

checkmark Patented “MA” (Mechanical Assembly) Technology for glue-free, environmentally-friendly packs that can be assembled on-site.
checkmark Can be field cut for a tight fit around columns and other structures without sacrificing structural integrity.

cooling tower drift Cooling Tower Drift

Applications

The XF80MAx is designed for applications requiring very low drift levels in crossflow Cooling Towers, Evaporative Cooling systems, Scrubbers, and High Humidity Cooling systems.

Product Weights / Span Capabilities

Sheet Thickness Dry Weight Maximum Span *
lbs/ft2 kg/m2
.013″ (.33mm) Standard 1.1 5.4 8 ft (2.4m)
.020″ (.51mm) Heavy Duty 1.5 7.3 10 ft (3.0m)

Product Dimensions

Cell Size Module Dimensions
Depth Width Standard Length
.86″ (21.8 mm) 5.25″ (133 mm) 24″ (610 mm) 2 to 12 ft.(610 to 3658 mm)
in 1 ft. (305 mm) increments
up to 6 ft. (1829 mm)
and in 2 ft. (610 mm) increments
over 6 ft. (1829 mm)

Drift Loss

Pressure Drop testing is currently being conducted on this newly-introduced product. As soon as the testing is completed and verified, the results will be published here.

Pressure Drop Curve

See CTI Technical Paper TP06-11 for comparative pressure drop tests of competing cellular drift eliminators.

Pressure Drop Curve

Materials

XF80MAx Crossflow Cellular Drift Eliminators are made from PVC material that meets CTI (Cooling Tower Institute) Standard 136 and is UV protected. The PVC compounds used in Brentwood cellular drift eliminators have outstanding resistance to weather exposure, and are nearly impervious to chemical degradation by alkalis and acids, grease, fats, oils, and biological attack. PVC has an excellent fire rating due to its self-extinguishing characteristics.

XF150MAx Counterflow Cellular Drift Eliminators

XF150MAx Crossflow Cellular Drift Eliminators are specifically-designed to achieve maximum drift removal efficiency in crossflow tower applications by providing an upward flow path and discharge angle of 40-55° from horizontal (depending on installation angle) and molded-in drainage channels that direct the collected drift back to the wet section of the tower even when impacted by water spray.

XF150MAx Counterflow Cellular Drift Eliminators

The modules are constructed of a series of sinusoidal-shaped corrugated CTI STD-136 PVC sheets that are mechanically assembled to mating sinusoidal structural waves to form closed cells. These cells force the drift droplets carried in the leaving airstream to make three distinct changes in direction. This disruption of the air flow creates centrifugal forces on the drift droplets, forcing them to be captured by inertial impaction and direct interception with the module walls and thereby removed from the airstream.

air flow

Features and Benefits

checkmark The upward flow path and discharge angle of 40-55° from horizontal (depending on installation angle) is specifically-designed for crossflow applications. The XF150MAx is fully-effective even when installed vertically.
checkmark Installed at the standard 10° from vertical (as shown at right on Brentwood XF-600 Supports), XF150MAx modules are strong enough to span 10 ft (3.0 m), requiring fewer support beams and less air blockage.
checkmark

XF150MAx modules “nest” with the modules next to them (below left) to provide “seamless” drift removal. This nesting design makes the nested space between packs a fully-functiioning drift removal cell instead of a “dead space” that can allow drift droplets to completely bypass the drift eliminators (below right).

Nested Seam & Flat Seam

checkmark Patented “MA” (Mechanical Assembly) Technology for environmentally-friendly, glue-free packs that can be assembled on-site
checkmark Can be field cut for a tight fit around columns and other structures without sacrificing structural integrity.
checkmark Patented “MA” (Mechanical Assembly) Technology for glue-free, environmentally-friendly packs that can be assembled on-site.
checkmark Can be field cut for a tight fit around columns and other structures without sacrificing structural integrity.
checkmark High surface area (cell dimension of 1.50″ [38mm]) provides maximum performance at minimum pressure drop.

cooling tower drift Cooling Tower Drift

Applications

The XF150MAx is designed for applications requiring very low drift levels in crossflow Cooling Towers, Evaporative Cooling systems, Scrubbers, and High Humidity Cooling systems.

Product Weights / Span Capabilities

Sheet Thickness Dry Weight Maximum Span *
lbs/ft2 kg/m2
.015″ (.38mm) Standard 1.0 4.9 8 ft (2.4m)
.020″ (.51mm) Heavy Duty 1.3 6.3 10 ft (3.0m)

Product Dimensions

Cell Size Module Dimensions
Depth Width Standard Length
1.500″ (38.1 mm) 5.25″ (133 mm) 12″ (305 mm)
18″ (457 mm)
2 to 12 ft.
in 2 ft. increments
(610 mm to 3658 mm
in 610 mm increments)

Drift Loss

.002% recirculation (Test Method CTI-HBIK Standard 140) is possible in new installations that are properly designed and installed and take advantage of the XF150MAx’s fully-nesting design and Brentwood DriSeals. Retrofitting older cooling towers with XF150MAx Crossflow Drift Eliminators will also result in significant improvement in drift emissions.

Pressure Drop Curve

See CTI Technical Paper TP06-11 for comparative pressure drop tests of competing cellular drift eliminators.

Pressure Drop Curve

Materials

XF150MAx Crossflow Cellular Drift Eliminators are made from PVC material that meets CTI (Cooling Tower Institute) Standard 136 and is UV protected. The PVC compounds used in Brentwood cellular drift eliminators have outstanding resistance to weather exposure, and are nearly impervious to chemical degradation by alkalis and acids, grease, fats, oils, and biological attack. PVC has an excellent fire rating due to its self-extinguishing characteristics.

Blade

DE-080 Blade Drift Eliminators

DE-080 Blade Drift Eliminator Modules use a tightly-spaced series of sinusoidal-shaped, PVC (or HPVC) blades that force the leaving air to make 3 distinct changes of direction, resulting in maximum drift droplet removal. But this performance does not come at the expense of fan energy, as the engineered flow through the DE-080 achieves very low pressure drop.

Blade

The blades are held together with one-piece end caps, forming an assembled module that is lightweight but strong enough to span up to 6 ft. (1.8 m) between supports, saving material & labor costs and reducing air blockage.

air flow

Features and Benefits

checkmark Easy to assemble on-site, Brentwood Blade Drift Eliminators are a popular choice for international projects (Shipping unassembled components vs. assembled modules can save significantly on freight costs).
checkmark

DE-080 modules “nest” with the modules next to them (below left) to provide “seamless” drift removal. This nesting design eliminates gaps between packs that can allow drift droplets to bypass the drift eliminators (below right).

Nested & Flat Seam

checkmark The DE-080 features an open drainage design for crossflow induced draft applications

Applications

The DE-080 is designed for applications requiring very low drift levels in counterflow or crossflow Cooling Towers, Evaporative Cooling systems, Turbine Intake Coolers, Scrubbers, and High Humidity Cooling systems.

Product Weights / Span Capabilities

Blade Thickness Dry Weight Maximum Span
lbs/ft2 kg/m2
.025″ (.64 mm) 1.40 6.8 6 ft (1.8m)

Product Dimensions

Blade Spacing Module Dimensions
Depth Width Length
.800 in (20 mm) 5.75 in (146 mm) 24 in (610 mm) 1 to 12 ft.
in 1 ft. increments
(305 mm to 3660 mm
in 305 mm increments)

Drift Loss

.002% recirculation (Test Method CTI-HBIK Standard 140)

Pressure Drop Curve

Pressure Drop Curve

Materials

DE-080 Blade Drift Eliminators are available in PVC and HPVC (for high temperatures) and are UV stabilized. These compounds have outstanding resistance to weather exposure and are nearly impervious to chemical degradation by alkali, acids, greases, fats, oils, and biological attack. They also have excellent fire rating due to their self-extinguishing characteristics, and meet or exceed Cooling Tower Institute Standard 136.

Parts Support Center

Give us a call, shoot a quick email, or submit your questions or parts requirements using our form and a STAR representative will respond promptly via email with prices, availability and product information.

More than 60 years of experience in securing the best prices on parts.

Get personalized help from a STAR Parts Specialist

Call: (713) 645-3323

Send us a message ›

Ready To Get Started?

divider

We’ve been designing, constructing, repairing and upgrading cooling towers for over 60 years. We would love to learn how we can help you too.

Request A Quote ›   (713) 645-3323